Home / Product / Moulded Case Circuit Breaker
JNSX Moulded Case Circuit Breaker
1.Application
UNS series plastic housing circuit breaker. They are characterized by compact size, modularization,high breaking, double break points, zero flashover, and green environmental protection. It issuitable for distribution networks with AC 50Hz, 60Hz, rated working voltage 690V and below, andrated current 12.5A to 1600A. It is used to distribute electric energy and protect lines and powerequipment from overload, short circuit, undervoltage, and other faults. It can also be used forinfrequent switching of lines and infrequent starting of motors under normal conditions. The JNS series circuit breaker is also equipped with an intelligent controller, which not onlyincreases the selection range of setting current, but also has LCD display, overload setting current,short circuit delay current, short circuit instantaneous current, and tripping time that can beset, as well as short circuit instantaneous three-stage protection and undervoltage protection; Equipped with RS485 communication interface and MODBUS-RTU protocol; DL645 protocol, userscan choose according to their needs. Remote signaling: breaking/closing, tripping, alarm, and faultstatus indication; Remote control: breaking, closing, resetting: Telemetry: three-phase current andN-phase current, grounding current, trip memory function, and functions such as querying triprecording parameters, further improving the reliability and continuity of power supply. This circuitbreaker also has an isolation function (can be used instead of a load switch). This series of products comply with GB/T14048.2, GB/T 22710, and IEC 60947-2 standards, andhave passed 3C, CE, and TSE certifications.
| JNSX-250 Type | |||||||||||
| Number of poles | 3P□4P | ||||||||||
| Shell frame maximum | rated current Inm(A) | 250 | |||||||||
| Rated current In(A) | TM MA Electronic type | 100/160/180/200/225/250 | |||||||||
| 250 | |||||||||||
| Rated insulation voltage Ui(V) | 1000 | ||||||||||
| Rated impulse withstand voltage Ulimp(kV) | 8 | ||||||||||
| 50H-60Hz Rated voltage Ue(V) 50H-60Hz | A | 400/4 | 415/500/690 | 690 | |||||||
| Flying arc Distance(mim) | |||||||||||
| Short circuit breaking capability level | N | - | M | H | S | ||||||
| AC400/415V | 35 | 50 | 85 | 100 | 150 | ||||||
| Rated limit Short circuit AC500V Breaking capacitylcu(kA) | / | 35 | 50 | 60 | 65 | ||||||
| AC690V | / | 6 | 8 | 10 | |||||||
| Usage Category | A | ||||||||||
| AC400/415V | 35 | 50 | 85 | 100 | 150 | ||||||
| Rated running shortcircuit AC500V Breaking capacityics(kA) | / | 35 | 50 | 60 | 65 | ||||||
| AC690V | / | 6 | 8 | 10 | |||||||
| Rated short time resistant current ICW(kA)(1s) | Type of Stripper | 3(micr | logic 5.0A | ||||||||
| Additional Residual cu Remaining Current protection | rent protection module(See P12-13 EL6 remaining current module for specific parameters) | ||||||||||
| Electrical Life Test | AC415V | 8000 | |||||||||
| AC690V | 1500 | ||||||||||
| Number of mechanical life | 2 | 0000 | |||||||||
| Type | JNSX-400 | JNSX-630 | JNSX- | 250/1600 | |||||||
| Number of poles | 3P,4P | 3P,4P | 月 | IP,4P | |||||||
| Shell frame maximum rated current Inm(A) | 400 | 630 | 125 | 0/1600 | |||||||
| TM MA Rated current In(A) | 250/315//350/400 | 400/500//600 | / | ||||||||
| Electronic type | 400 | 630 | 630/800/1 | 000/1250/1600 | |||||||
| Rated insulation voltage Ui(V) | 1000 | 1000 | :1000 | ||||||||
| Rated impulse withstand voltage Ump(kV) | 8 | 8 | 8 | ||||||||
| 50H-60Hz Rated voltage Ue(V)50H-60Hz | AC400/415/500/690V | AC400/415/500/690V | AC400/ | 415/500/690V | |||||||
| Flying arc Distance(mm) | 0 | ||||||||||
| Short circuit breaking capability level L M H S L M H S M H | |||||||||||
| Rated limit Short circuit | AC400/415V 50 | 85 100 | 150 50 | 85 | 100 150 50 65 | ||||||
| Breaking capacityicu(xA) | AC500V 35 | 50 60 | 65 35 | 50 | 60 65 | 35 45 | |||||
| AC690V | 10 15 | 20 | 10 | 15 20 | 20 30 | ||||||
| Rated running shortcircuit | AC400/415V 50 | 85 100 | 150 | 50 | 85 | 100 150 | 50 65 | ||||
| Breaking | AC500V 35 | 50 60 | 65 | 35 | 50 | 60 65 | 35 45 | ||||
| capacityics(kA) | AC690V | 10 15 | 20 | 10 | 15 20 | 20 30 | |||||
| Working with categories | TM/MA micrologic 2 micrologic 3 | A | A | / | |||||||
| micrologic 5.0A | B | 11 | B | ||||||||
| Rated short time resistant current ICW(kA)(1s) 5(micrologic 5.0A) 5(micrologic 5.0A) 20(micro logic 5.0A) | |||||||||||
| Remaining Current | protection Addit | onal Residual current | pro | ction speci | tule(Se ic para | P12-13 meters) | L6 remain | aining current | module for | ||
| Electrical Life Test | AC415V | 6000 | 5000 | 1500 | |||||||
| AC690V | 1000 | 1000 | 1000 | ||||||||
We take pride in our customer service and aim to provide 5-star support. If you have any questions about our products, feel free to call or email us.
The company mainly produces AC contactors, motor protectors and thermal relays.All products have passed the CE safety certification, and some have passed the CB certification.